Developing an artificial arm with functions equivalent to those of the human arm is one of the challenging goals of bioengineering. State-of-the-artprostheses lack several degrees of freedom and force the individuals to compensate for them by means of compensatory movements, which often result in residual limb pain and overuse syndromes. Passive wristsmay reduce such compensatory actions, nonethelessto date their actual efficacy, associated to conventional myoelectric hands is a matter of debate. We hypothesized that a transradial prosthesiswould allow a simpler operation if its wrist behaved compliant during the reaching and grasping phase, and stiff during the holding andmanipulation phase. To assess this, we compared a stiff and a compliant wrist and evaluating the extent of compensatory movements in the trunk and shoulder, with unimpaired subjects wearing orthoses, while performing nine activities of daily living taken from the southampton hand assessment procedure. Our findings show indeed that the optimal compliance for a prosthetic wrist is specific to the phase of the motor task: the compliant wrist outperforms the stiff wrist during the reaching phase, whereas the stiff wrist exhibits more natural movements during the manipulation phase of heavy objects. Hence, this paper invites rehabilitation engineers to develop wrists with switchable compliance.
Compliant Prosthetic Wrists Entail More Natural Use Than Stiff Wrists during Reaching, Not (Necessarily) during Manipulation
Kanitz, Gunter;Montagnani, Federico;Controzzi, Marco;Cipriani, Christian
2018-01-01
Abstract
Developing an artificial arm with functions equivalent to those of the human arm is one of the challenging goals of bioengineering. State-of-the-artprostheses lack several degrees of freedom and force the individuals to compensate for them by means of compensatory movements, which often result in residual limb pain and overuse syndromes. Passive wristsmay reduce such compensatory actions, nonethelessto date their actual efficacy, associated to conventional myoelectric hands is a matter of debate. We hypothesized that a transradial prosthesiswould allow a simpler operation if its wrist behaved compliant during the reaching and grasping phase, and stiff during the holding andmanipulation phase. To assess this, we compared a stiff and a compliant wrist and evaluating the extent of compensatory movements in the trunk and shoulder, with unimpaired subjects wearing orthoses, while performing nine activities of daily living taken from the southampton hand assessment procedure. Our findings show indeed that the optimal compliance for a prosthetic wrist is specific to the phase of the motor task: the compliant wrist outperforms the stiff wrist during the reaching phase, whereas the stiff wrist exhibits more natural movements during the manipulation phase of heavy objects. Hence, this paper invites rehabilitation engineers to develop wrists with switchable compliance.File | Dimensione | Formato | |
---|---|---|---|
Kantiz et al 2018 web.pdf
accesso aperto
Descrizione: Post print
Tipologia:
Documento in Post-print/Accepted manuscript
Licenza:
PUBBLICO - Pubblico con Copyright
Dimensione
1.33 MB
Formato
Adobe PDF
|
1.33 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.