This paper presents a novel methodology for estimating the gait phase of human walking through a simple sensory apparatus. Three subsystems are combined: a primary phase estimator based on adaptive oscillators, a desired gait event detector and a phase error compensator. The estimated gait phase is expected to linearly increase from 0 to 2(Formula presented.) rad in one stride and remain continuous also when transiting to the next stride. We designed two experimental scenarios to validate this gait phase estimator, namely treadmill walking at different speeds and free walking. In the case of treadmill walking, the maximum phase error at the desired gait events was found to be 0.155 rad, and the maximum phase difference between the end of the previous stride and beginning of the current stride was 0.020 rad. In the free walking trials, phase error at the desired gait event was never larger than 0.278 rad. Our algorithm outperformed against two other benchmarked methods. The good performance of our gait phase estimator could provide consistent and finely tuned assistance for an exoskeleton designed to augment the mobility of patients.

An oscillator-based smooth real-time estimate of gait phase for wearable robotics

YAN, Tingfang;PARRI, ANDREA;CEMPINI, Marco;VITIELLO, Nicola
2016-01-01

Abstract

This paper presents a novel methodology for estimating the gait phase of human walking through a simple sensory apparatus. Three subsystems are combined: a primary phase estimator based on adaptive oscillators, a desired gait event detector and a phase error compensator. The estimated gait phase is expected to linearly increase from 0 to 2(Formula presented.) rad in one stride and remain continuous also when transiting to the next stride. We designed two experimental scenarios to validate this gait phase estimator, namely treadmill walking at different speeds and free walking. In the case of treadmill walking, the maximum phase error at the desired gait events was found to be 0.155 rad, and the maximum phase difference between the end of the previous stride and beginning of the current stride was 0.020 rad. In the free walking trials, phase error at the desired gait event was never larger than 0.278 rad. Our algorithm outperformed against two other benchmarked methods. The good performance of our gait phase estimator could provide consistent and finely tuned assistance for an exoskeleton designed to augment the mobility of patients.
2016
File in questo prodotto:
File Dimensione Formato  
10514_2016_9566_OnlinePDF.pdf

solo utenti autorizzati

Descrizione: Revised proofs
Tipologia: Documento in Post-print/Accepted manuscript
Licenza: Creative commons (selezionare)
Dimensione 2.76 MB
Formato Adobe PDF
2.76 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/510155
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 111
social impact