Nowadays advanced heart failure is mainly treated through heart transplantation. However, the low availability of donors makes the research of alternative therapies urgent. Continuous-flow left ventricular assist devices (LVADs) are going to assume a more significant role in assisting the failing heart. A recent challenge in clinical practice is the possibility to use LVAD as long-term therapy rather than as a bridge to transplantation. For this reason, more comfortable devices, able to dynamically adapt to the physiological cardiac demand in relation to the patient activity level, are needed in order to improve the life quality of patients with implants. Nevertheless, no control system has been developed yet for this purpose. This work proposes an innovative control strategy for a novel sensorized LVAD, based on the continuous collection of physical and functional parameters coming from implantable sensors and from the LVAD itself. Thanks to the proposed system, both the patient and the LVAD conditions are continuously monitored and the LVAD activity regulated accordingly. Specifically, a Proportional Integrative (PI) and a threshold control algorithms have been implemented, respectively based on flow and pressure feedbacks collected from the embedded sensors. To investigate the feasibility and applicability of this control strategy, an on-bench platform for LVADs sensing and monitoring has been developed and tested.

An innovative adaptive control strategy for sensorized left ventricular assist devices

VERBENI, Antonella;FONTANA, Rossella;SILVESTRI, Michele;TORTORA, GIUSEPPE ROBERTO;VATTERONI, Monica;TRIVELLA, Maria Giovanna;DARIO, Paolo
2014-01-01

Abstract

Nowadays advanced heart failure is mainly treated through heart transplantation. However, the low availability of donors makes the research of alternative therapies urgent. Continuous-flow left ventricular assist devices (LVADs) are going to assume a more significant role in assisting the failing heart. A recent challenge in clinical practice is the possibility to use LVAD as long-term therapy rather than as a bridge to transplantation. For this reason, more comfortable devices, able to dynamically adapt to the physiological cardiac demand in relation to the patient activity level, are needed in order to improve the life quality of patients with implants. Nevertheless, no control system has been developed yet for this purpose. This work proposes an innovative control strategy for a novel sensorized LVAD, based on the continuous collection of physical and functional parameters coming from implantable sensors and from the LVAD itself. Thanks to the proposed system, both the patient and the LVAD conditions are continuously monitored and the LVAD activity regulated accordingly. Specifically, a Proportional Integrative (PI) and a threshold control algorithms have been implemented, respectively based on flow and pressure feedbacks collected from the embedded sensors. To investigate the feasibility and applicability of this control strategy, an on-bench platform for LVADs sensing and monitoring has been developed and tested.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/499541
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
social impact