Extensive efforts in providing upper limb amputees with sensory feedback have primarily focused on the restoration of tactile capabilities, while challenges in evoking proprioceptive sensations have been poorly addressed. Previously, an human–machine interface (HMI) was proposed based on permanent magnets implanted in residual muscles of an amputee, namely the myokinetic interface, to control robotic limb prostheses. Besides control, implanted magnets offer an unprecedent opportunity to trigger musculotendon proprioceptors via untethered selective vibrations. Herein, the challenge of tracking multiple moving magnets is addressed (e.g., following muscle contractions) while being vibrated by controlled magnetic fields produced by external coils. Results demonstrate the viability of a real-time (RT) system capable of simultaneously tracking and vibrating multiple moving magnets within a three-dimensional workspace. Highly selective torsional vibrations in the frequency span eliciting movement illusions (70, 80, and 90 Hz) are achieved on two moving magnets, with efficiencies above 0.82 (over 80% of spectral power at the desired frequency). Tracking accuracy and precision remain robust to the coil magnetic field, with position median errors below 1.2 mm and median displacement errors below 0.95 mm. This study represents a crucial step towards the development of a bench system to study proprioception in humans.

Generating Frequency Selective Vibrations in Remote Moving Magnets

Masiero, Federico;La Frazia, Eliana;Ianniciello, Valerio;Cipriani, Christian
2024-01-01

Abstract

Extensive efforts in providing upper limb amputees with sensory feedback have primarily focused on the restoration of tactile capabilities, while challenges in evoking proprioceptive sensations have been poorly addressed. Previously, an human–machine interface (HMI) was proposed based on permanent magnets implanted in residual muscles of an amputee, namely the myokinetic interface, to control robotic limb prostheses. Besides control, implanted magnets offer an unprecedent opportunity to trigger musculotendon proprioceptors via untethered selective vibrations. Herein, the challenge of tracking multiple moving magnets is addressed (e.g., following muscle contractions) while being vibrated by controlled magnetic fields produced by external coils. Results demonstrate the viability of a real-time (RT) system capable of simultaneously tracking and vibrating multiple moving magnets within a three-dimensional workspace. Highly selective torsional vibrations in the frequency span eliciting movement illusions (70, 80, and 90 Hz) are achieved on two moving magnets, with efficiencies above 0.82 (over 80% of spectral power at the desired frequency). Tracking accuracy and precision remain robust to the coil magnetic field, with position median errors below 1.2 mm and median displacement errors below 0.95 mm. This study represents a crucial step towards the development of a bench system to study proprioception in humans.
2024
File in questo prodotto:
File Dimensione Formato  
Advanced Intelligent Systems - 2024 - Masiero - Generating Frequency Selective Vibrations in Remote Moving Magnets.pdf

accesso aperto

Tipologia: Documento in Pre-print/Submitted manuscript
Licenza: Creative commons (selezionare)
Dimensione 2.92 MB
Formato Adobe PDF
2.92 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/575536
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact