The Cyclic Alternating Pattern (CAP) is composed of cycles of two different electroencephalographic features: an activation A-phase followed by a B-phase representing the background activity. CAP is considered a physiological marker of sleep instability. Despite its informative nature, the clinical applications remain limited as CAP analysis is a time-consuming activity. In order to overcome this limit, several automatic detection methods were recently developed. In this paper, two new dimensions were investigated in the attempt to optimize novel, efficient and automatic detection algorithms: 1) many electroencephalographic leads were compared to identify the best local performance, and 2) the global contribution of the concurrent detection across several derivations to CAP identification. The developed algorithms were tested on 41 polysomnographic recordings from normal (n = 8) and pathological (n = 33) subjects. In comparison with the visual CAP analysis as the gold standard, the performance of each algorithm was evaluated. Locally, the detection on the F4-C4 derivation showed the best performance in comparison with all other leads, providing practical suggestions of electrode montage when a lean and minimally invasive approach is preferable. A further improvement in the detection was achieved by a multi-trace method, the Global Analysis—Common Events, to be applied when several recording derivations are available. Moreover, CAP time and CAP rate obtained with these algorithms positively correlated with the ones identified by the scorer. These preliminary findings support efficient automated ways for the evaluation of the sleep instability, generalizable to both normal and pathological subjects affected by different sleep disorders.

Automatic Cyclic Alternating Pattern (CAP) analysis: Local and multi-trace approaches

Faraguna U.;Ciuti G.;
2021-01-01

Abstract

The Cyclic Alternating Pattern (CAP) is composed of cycles of two different electroencephalographic features: an activation A-phase followed by a B-phase representing the background activity. CAP is considered a physiological marker of sleep instability. Despite its informative nature, the clinical applications remain limited as CAP analysis is a time-consuming activity. In order to overcome this limit, several automatic detection methods were recently developed. In this paper, two new dimensions were investigated in the attempt to optimize novel, efficient and automatic detection algorithms: 1) many electroencephalographic leads were compared to identify the best local performance, and 2) the global contribution of the concurrent detection across several derivations to CAP identification. The developed algorithms were tested on 41 polysomnographic recordings from normal (n = 8) and pathological (n = 33) subjects. In comparison with the visual CAP analysis as the gold standard, the performance of each algorithm was evaluated. Locally, the detection on the F4-C4 derivation showed the best performance in comparison with all other leads, providing practical suggestions of electrode montage when a lean and minimally invasive approach is preferable. A further improvement in the detection was achieved by a multi-trace method, the Global Analysis—Common Events, to be applied when several recording derivations are available. Moreover, CAP time and CAP rate obtained with these algorithms positively correlated with the ones identified by the scorer. These preliminary findings support efficient automated ways for the evaluation of the sleep instability, generalizable to both normal and pathological subjects affected by different sleep disorders.
2021
File in questo prodotto:
File Dimensione Formato  
journal.pone.0260984.pdf

accesso aperto

Licenza: Creative commons (selezionare)
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/549211
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
social impact