Background: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line. Methods: Consecutive patients undergoing the first ablation procedure of catheter ablation (CA) for PeAF were enrolled. All patients underwent VOM-EI, PVI, and ablation lines along the roof of the LA, mitral, and cavotricuspid isthmus. LA voltage mapping before and after VOM-EI was also performed. An implantable loop recorder (ILR) was implanted at the end of the ablation in each patient. Results: Thirty-one consecutive patients (66 ± 8 years and 71% male) affected by PeAF were included in this study. The VOM-EI procedural phase lasted 21.4 ± 10.1 min. PV isolation and lines were validated in all subjects. The ML block was achieved within 10.8 ± 8.7 min. At a mean follow-up of 12 ± 7 months, 27 out of 31 (87%) patients remained free from AT/AF recurrences. Among the patients with recurrences, two (50%) had incomplete ablation lesions and three (75%) had “suboptimal” VOM-EI. In 23/31 patients (74%), antiarrhythmic drugs (AADs) were discontinued after 1 month of follow-up. No significant complications were reported during the follow-up. Conclusions: this single-center experience demonstrates that VOM-EI systematically combined with an anatomical ablation set in patients with PeAF resulted in feasible, safe, and effective freedom from AF/AT recurrences in 87% of the population after a 1-year follow-up period according to an ILR.

Impact of Vein of Marshall Ethanol Infusion Combined with Anatomical Ablation for the Treatment of Persistent Atrial Fibrillation: A Long-Term Follow-Up Based on Implantable Loop Recorders

Mirizzi G.;Giannoni A.;
2023-01-01

Abstract

Background: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line. Methods: Consecutive patients undergoing the first ablation procedure of catheter ablation (CA) for PeAF were enrolled. All patients underwent VOM-EI, PVI, and ablation lines along the roof of the LA, mitral, and cavotricuspid isthmus. LA voltage mapping before and after VOM-EI was also performed. An implantable loop recorder (ILR) was implanted at the end of the ablation in each patient. Results: Thirty-one consecutive patients (66 ± 8 years and 71% male) affected by PeAF were included in this study. The VOM-EI procedural phase lasted 21.4 ± 10.1 min. PV isolation and lines were validated in all subjects. The ML block was achieved within 10.8 ± 8.7 min. At a mean follow-up of 12 ± 7 months, 27 out of 31 (87%) patients remained free from AT/AF recurrences. Among the patients with recurrences, two (50%) had incomplete ablation lesions and three (75%) had “suboptimal” VOM-EI. In 23/31 patients (74%), antiarrhythmic drugs (AADs) were discontinued after 1 month of follow-up. No significant complications were reported during the follow-up. Conclusions: this single-center experience demonstrates that VOM-EI systematically combined with an anatomical ablation set in patients with PeAF resulted in feasible, safe, and effective freedom from AF/AT recurrences in 87% of the population after a 1-year follow-up period according to an ILR.
2023
File in questo prodotto:
File Dimensione Formato  
NestiMarshall2023.pdf

accesso aperto

Tipologia: Documento in Pre-print/Submitted manuscript
Licenza: Dominio pubblico
Dimensione 772.38 kB
Formato Adobe PDF
772.38 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/572413
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
social impact