Purpose: The aim of this paper is to investigate the acute effects of short-term transcutaneous vagus nerve stimulation (tVNS) on cardio-vagal baroreflex gain and heart rate variability in patients with chronic heart failure (CHF). Methods: A total of 16 adults with CHF and left ventricular ejection fraction (LVEF) < 50% in sinus rhythm were enrolled (65 ± 8 years, 63% men, LVEF 40 ± 5%, 88% on beta-blockers, 50% on quadruple CHF therapy). Over a single experimental session, after a 10-min baseline recording, each patient underwent two trials of 10-min tVNS (Parasym Device, 200 µs, 30 Hz, 1 mA below discomfort threshold) at either the right or left tragus in a randomized order, separated by a 10-min recovery. Results: Compared with baseline, tVNS did not affect heart rate, blood pressure, and respiratory rate (p > 0.05), and no patients complained of discomfort or any adverse effect. Right-sided tVNS was associated with a significant increase in cardio-vagal baroreflex gain (from 5.6 ± 3.1 to 7.5 ± 3.8 ms/mmHg, ∆ 1.9 ± 1.6 ms/mmHg, p < 0.001), while no change was observed with left-sided tVNS (∆ 0.5 ± 2.0 ms/mmHg, p = 0.914). These findings were independent of stimulation-side order (excluding any carry-over effect) and consistent across sex, LVEF category, and HF etiology subgroups (p-value for interaction > 0.05). Conclusions: Acute right-sided tVNS increases cardio-vagal baroreflex gain in patients with CHF and LVEF < 50%, with no tolerability concerns.

Acute right-sided transcutaneous vagus nerve stimulation improves cardio-vagal baroreflex gain in patients with chronic heart failure

Gentile F.;Giannoni A.;Emdin M.;Passino C.
2024-01-01

Abstract

Purpose: The aim of this paper is to investigate the acute effects of short-term transcutaneous vagus nerve stimulation (tVNS) on cardio-vagal baroreflex gain and heart rate variability in patients with chronic heart failure (CHF). Methods: A total of 16 adults with CHF and left ventricular ejection fraction (LVEF) < 50% in sinus rhythm were enrolled (65 ± 8 years, 63% men, LVEF 40 ± 5%, 88% on beta-blockers, 50% on quadruple CHF therapy). Over a single experimental session, after a 10-min baseline recording, each patient underwent two trials of 10-min tVNS (Parasym Device, 200 µs, 30 Hz, 1 mA below discomfort threshold) at either the right or left tragus in a randomized order, separated by a 10-min recovery. Results: Compared with baseline, tVNS did not affect heart rate, blood pressure, and respiratory rate (p > 0.05), and no patients complained of discomfort or any adverse effect. Right-sided tVNS was associated with a significant increase in cardio-vagal baroreflex gain (from 5.6 ± 3.1 to 7.5 ± 3.8 ms/mmHg, ∆ 1.9 ± 1.6 ms/mmHg, p < 0.001), while no change was observed with left-sided tVNS (∆ 0.5 ± 2.0 ms/mmHg, p = 0.914). These findings were independent of stimulation-side order (excluding any carry-over effect) and consistent across sex, LVEF category, and HF etiology subgroups (p-value for interaction > 0.05). Conclusions: Acute right-sided tVNS increases cardio-vagal baroreflex gain in patients with CHF and LVEF < 50%, with no tolerability concerns.
2024
File in questo prodotto:
File Dimensione Formato  
GentileCAR2024.pdf

accesso aperto

Tipologia: Documento in Pre-print/Submitted manuscript
Licenza: Dominio pubblico
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/572407
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0