We investigated optical damage (surface and bulk) in one of the most promising wide bandgap nonoxide nonlinear crystals, HgGa2S 4, that can be used in ~1-μ m pumped optical parametric oscillators (OPOs) and synchronously pumped OPOs (SPOPOs) for generation of idler pulses above 4 μ m without two-photon absorption losses at the pump wavelength. The optical damage has been characterized at the pump wavelength for different repetition rates using uncoated and antireflectioncoated (mainly with a single layer for pump and signal wavelengths) samples. HgGa2S 4 is the most successful nonlinear crystal (both in terms of output energy and average power) for such OPOs, but optical damage inside the OPO has a lower threshold and represents at present the principal limitation for the achievable output. It is related to peak pulse and not to average intensity, and bulk damage in the form of scattering centers occurs before surface damage. Such bulk damage formation is faster at higher repetition rates. Lower repetition rates increase the lifetime of the crystal but do not solve the problem. The safe pump fluence in extracavity measurements is © 2013 SPIE.
Optical damage studies of mercury thiogallate nonlinear crystals for use in 1-μ m pumped optical parametric oscillators
Reza M.;
2013-01-01
Abstract
We investigated optical damage (surface and bulk) in one of the most promising wide bandgap nonoxide nonlinear crystals, HgGa2S 4, that can be used in ~1-μ m pumped optical parametric oscillators (OPOs) and synchronously pumped OPOs (SPOPOs) for generation of idler pulses above 4 μ m without two-photon absorption losses at the pump wavelength. The optical damage has been characterized at the pump wavelength for different repetition rates using uncoated and antireflectioncoated (mainly with a single layer for pump and signal wavelengths) samples. HgGa2S 4 is the most successful nonlinear crystal (both in terms of output energy and average power) for such OPOs, but optical damage inside the OPO has a lower threshold and represents at present the principal limitation for the achievable output. It is related to peak pulse and not to average intensity, and bulk damage in the form of scattering centers occurs before surface damage. Such bulk damage formation is faster at higher repetition rates. Lower repetition rates increase the lifetime of the crystal but do not solve the problem. The safe pump fluence in extracavity measurements is © 2013 SPIE.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.