Background In neonatal endotracheal intubation, excessive pressure on soft tissues during laryngoscopy can determine permanent injury. Low-fidelity skill trainers do not give valid feedback about this issue. This study describes the technical realization and validation of an active neonatal intubation skill trainer providing objective feedback. Methods We studied expert health professionals' performances in neonatal intubation, underlining chance for procedure retraining. We identified the most critical points in epiglottis and dental arches and fixed commercial force sensors on chosen points on a ©Laerdal Neonatal Intubation Trainer. Our skill trainer was set up as a grade 3 on Cormack and Lehane's scale, i.e. a model of difficult intubation. An associated software provided real time sound feedback if pressure during laryngoscopy exceeded an established threshold. Pressure data were recorded in a database, for subsequent analysis with non-parametric statistical tests. We organized our study in two intubation sessions (5 attempts each one) for everyone of our participants, held 24 h apart. Between the two sessions, a debriefing phase took place. In addition, we gave our participants two interview, one at the beginning and one at the end of the study, to get information about our subjects and to have feedback about our design. Results We obtained statistical significant differences between consecutive attempts, with evidence of learning trends. Pressure on critical points was significantly lower during the second session (p < 0.0001). Epiglottis' sensor was the most stressed (p < 0.000001). We found a significant correlation between time spent for each attempt and pressures applied to the airways in the two sessions, more significant in the second one (shorter attempts with less pressure, r s = 0.603). Conclusions Our skill trainer represents a reliable model of difficult intubation. Our results show its potential to optimize procedures related to the control of trauma risk and to improve personnel retraining.

Technical realization of a sensorized neonatal intubation skill trainer for operators' retraining and a pilot study for its validation

Panizza D.;Scaramuzzo R. T.;Baldoli I.;Tognarelli S.;Boldrini A.;
2018-01-01

Abstract

Background In neonatal endotracheal intubation, excessive pressure on soft tissues during laryngoscopy can determine permanent injury. Low-fidelity skill trainers do not give valid feedback about this issue. This study describes the technical realization and validation of an active neonatal intubation skill trainer providing objective feedback. Methods We studied expert health professionals' performances in neonatal intubation, underlining chance for procedure retraining. We identified the most critical points in epiglottis and dental arches and fixed commercial force sensors on chosen points on a ©Laerdal Neonatal Intubation Trainer. Our skill trainer was set up as a grade 3 on Cormack and Lehane's scale, i.e. a model of difficult intubation. An associated software provided real time sound feedback if pressure during laryngoscopy exceeded an established threshold. Pressure data were recorded in a database, for subsequent analysis with non-parametric statistical tests. We organized our study in two intubation sessions (5 attempts each one) for everyone of our participants, held 24 h apart. Between the two sessions, a debriefing phase took place. In addition, we gave our participants two interview, one at the beginning and one at the end of the study, to get information about our subjects and to have feedback about our design. Results We obtained statistical significant differences between consecutive attempts, with evidence of learning trends. Pressure on critical points was significantly lower during the second session (p < 0.0001). Epiglottis' sensor was the most stressed (p < 0.000001). We found a significant correlation between time spent for each attempt and pressures applied to the airways in the two sessions, more significant in the second one (shorter attempts with less pressure, r s = 0.603). Conclusions Our skill trainer represents a reliable model of difficult intubation. Our results show its potential to optimize procedures related to the control of trauma risk and to improve personnel retraining.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/531395
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
social impact