Tungsten is an elective material to produce slender and stiff microneedles able to enter soft tissues and minimize puncture wounds. In particular, tungsten microneedles are used to puncture peripheral nerves and insert neural interfaces, bridging the gap between the nervous system and robotic devices (e.g., hand prostheses). Unfortunately, microneedles fail during the puncture process and this failure is not dependent on stiffness or fracture toughness of the constituent material. In addition, the microneedles' performances decrease during in vivo trials with respect to the in vitro ones. This further effect is independent on internal biotic effects, while it seems to be related to external biotic causes. Since the exact synergy of phenomena decreasing the in vivo reliability is still not known, this work explored the connection between in vitro and in vivo behavior of tungsten microneedles through the study of interactions between biotic and abiotic factors. A hybrid computational approach, simultaneously using theoretical relationships and in silico models of nerves, was implemented to model the change of reliability varying the microneedle diameter, and to predict in vivo performances by using in vitro reliability and local differences between in vivo and in vitro mechanical response of nerves.

Interactions among biotic and abiotic factors affect the reliability of tungsten microneedles puncturing in vitro and in vivo peripheral nerves: A hybrid computational approach

Sergi, Pier Nicola
Writing – Original Draft Preparation
;
2016-01-01

Abstract

Tungsten is an elective material to produce slender and stiff microneedles able to enter soft tissues and minimize puncture wounds. In particular, tungsten microneedles are used to puncture peripheral nerves and insert neural interfaces, bridging the gap between the nervous system and robotic devices (e.g., hand prostheses). Unfortunately, microneedles fail during the puncture process and this failure is not dependent on stiffness or fracture toughness of the constituent material. In addition, the microneedles' performances decrease during in vivo trials with respect to the in vitro ones. This further effect is independent on internal biotic effects, while it seems to be related to external biotic causes. Since the exact synergy of phenomena decreasing the in vivo reliability is still not known, this work explored the connection between in vitro and in vivo behavior of tungsten microneedles through the study of interactions between biotic and abiotic factors. A hybrid computational approach, simultaneously using theoretical relationships and in silico models of nerves, was implemented to model the change of reliability varying the microneedle diameter, and to predict in vivo performances by using in vitro reliability and local differences between in vivo and in vitro mechanical response of nerves.
2016
File in questo prodotto:
File Dimensione Formato  
JHS_MSEC_016_ABSTRAC.pdf

accesso aperto

Tipologia: Abstract e indice (per monografie)
Licenza: Dominio pubblico
Dimensione 31.81 kB
Formato Adobe PDF
31.81 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/527335
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
social impact