Current fitting procedures of powered partial hand prostheses heavily rely on manual “trial & error” approaches by skilled prosthetists without taking advantage of more modern engineering enabling technologies. Here we preliminary present an optimization method for the placement of the powered digits based on a biomechanical simplified model. The mathematical model is built taking into account the geometry of the residual limb, the functional conditions of the stump and the kinematics of the prosthesis. The optimization refers to the distance, on the palm plane, between the basements of two opposing digits. In particular it focused on the opposition capability of a prosthetic index digit with an unpaired thumb in a pinch grasp. The optimal posture is the one that allows the maximum control accuracy of the force along the direction of the grasp. We argue that the proposed method could be used to predict the quality of the fitting and to standardize the process.

Method for optimal digit alignment for the fitting of partial hand powered prostheses: A preliminary study

Imbinto, I.;Controzzi, M.;Cipriani, C.
2019-01-01

Abstract

Current fitting procedures of powered partial hand prostheses heavily rely on manual “trial & error” approaches by skilled prosthetists without taking advantage of more modern engineering enabling technologies. Here we preliminary present an optimization method for the placement of the powered digits based on a biomechanical simplified model. The mathematical model is built taking into account the geometry of the residual limb, the functional conditions of the stump and the kinematics of the prosthesis. The optimization refers to the distance, on the palm plane, between the basements of two opposing digits. In particular it focused on the opposition capability of a prosthetic index digit with an unpaired thumb in a pinch grasp. The optimal posture is the one that allows the maximum control accuracy of the force along the direction of the grasp. We argue that the proposed method could be used to predict the quality of the fitting and to standardize the process.
2019
978-3-030-01844-3
978-3-030-01845-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/527255
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact